BoltedEndPlate Methods |
The BoltedEndPlate type exposes the following members.
Name | Description | |
---|---|---|
![]() | FbRd |
Bearing resistance of the bolt group
|
![]() | FirstRowBelowUpperFlange |
Checks if the given row is the first below the upper column flange
|
![]() | FvRd |
Shear resistance of the bolt group
|
![]() | GetInputWarnings |
Returns a list of strings that describe the input warnings regarding the bolt placement on the plate
|
![]() | px |
Horizontal inner distance between bolts
|
![]() | py |
Vertical inner distance for a bolt row
|
![]() | RowInsideFlanges |
Checks if a bolt row is located along the beam height
|
![]() | RowOnBeamHeight |
Checks if the bolt row is located along the beam height
|
![]() | RowOnHaunchHeight |
Checks if the bolt row is located along the haunch height
|
![]() | RowOutsideUpperFlange |
Checks if a bolt row is located outside the upper beam flange
|
![]() | Rows |
Total bolt rows count
|
![]() | VerticalRowDistances |
Calculation of the distance of each row from the upper edge of the endplate
|