Click or drag to resize

BoltedEndPlate Methods

EC3 Steel Connection Design Library

The BoltedEndPlate type exposes the following members.

Methods
  NameDescription
Public methodFbRd
Bearing resistance of the bolt group
Public methodFirstRowBelowUpperFlange
Checks if the given row is the first below the upper column flange
Public methodFvRd
Shear resistance of the bolt group
Public methodGetInputWarnings
Returns a list of strings that describe the input warnings regarding the bolt placement on the plate
Public methodpx
Horizontal inner distance between bolts
Public methodpy
Vertical inner distance for a bolt row
Public methodRowInsideFlanges
Checks if a bolt row is located along the beam height
Public methodRowOnBeamHeight
Checks if the bolt row is located along the beam height
Public methodRowOnHaunchHeight
Checks if the bolt row is located along the haunch height
Public methodRowOutsideUpperFlange
Checks if a bolt row is located outside the upper beam flange
Public methodRows
Total bolt rows count
Public methodVerticalRowDistances
Calculation of the distance of each row from the upper edge of the endplate
Top