Click or drag to resize

BeamColumnWeldedConnectionLoadCasesLeftBeam Field

EC3 Steel Connection Design Library
Load cases of left beam, in case of double side connection

Namespace:  SteelConnectionsEC3
Assembly:  SteelConnectionsEC3 (in SteelConnectionsEC3.dll) Version: 1.0.0.0 (1.0.0.0)
Syntax
public List<LoadCase> LoadCasesLeftBeam

Field Value

Type: ListLoadCase
Remarks
Following forces are considered:

Ned (positive=compressive), WARNING: Ned should not exceed 5% of the beam plastic axial resistance, according to 6.2.3(2) [prEN 1993-1-8 : 2003]!!

Ved (positive=downwards)

Med (positive=lower beam flange is compressed), WARNING: Med has to be positive!!

See Also