Click or drag to resize

StationDuctilityDesignResults Fields

Eurocode 3 and Eurocode 8 Design Library

The StationDuctilityDesignResults type exposes the following members.

Fields
  NameDescription
Public fieldCheckSatisfied_Y
True, if check of (6.7), paragrapph 6.6.3 is satisfied for direction y, otherwise false
Public fieldCheckSatisfied_Z
True, if check of (6.7), paragrapph 6.6.3 is satisfied for direction z, otherwise false
Public fieldVedEy
Design shear force parallel to local y axis according to (6.6), paragraph 6.6.3
Public fieldVedEz
Design shear force parallel to local z axis according to (6.6), paragraph 6.6.3
Public fieldVRdy
Shear force design resistance parallel to local y axis
Public fieldVRdz
Shear force design resistance parallel to local z axis
Top